Emergency Stop Module, BN5983.53 Machine emergency stop switches Monitors safety doors SK 3 (with equivalent switching) Output: 3 N/Os, 1 N/C for AC 380 V 1 or 2-channel configuration LED indicators for channels 1 and 2 Control loop X3-X4 for monitoring external protection Removable terminals Protection of humans and machines in accordance with: EC Directive on Machines 89/392/EEC, IEC 204, EN 60204, DIN VDE 0113 Input: Nom. voltage: AC 230 V or DC 24 V Control voltage on S11: 24 Vdc Min. Voltage on S12, S21: DC 21 V (activated device) Output: Contact assignment: 3 N/Os, 1 N/C, 1 wiping contact (approx. 200 ms) Response time: 35 ms Downtime in case of interruption: ...in secondary circuit (S12-S22): 30 ms ±25% ...in network: 100 ms ±50% Switching capability according to AC 15: 5 A / AC 230 V General data: Temperature range: -15 °C → +55 °C Terminal positioning: Compliant with DIN 46199-4 Device dimensions (W x H x D): 100 x 74 x 121 mm Approvals BG, TÜV-Rheinland, UL, CSA, SUVA, SA Sweden, Arbejdstilsynet Denmark Standards EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1